Controller Features:

  • Disconnect Switch / Circuit Breaker
  • Motor Starter
  • 7" Capacitive Color Touchscreen
  • Weekly Test Timer
  • Data Logging
  • True RMS Metering
Home | Products | MarkIII+ Electric Fire Pump Controllers | FTA1800 (MarkIII+)

FTA1800 (MarkIII+)

Autotransformer Starting

Firetrol® FTA1800 Autotransformer Starting Fire Pump Controllers use an autotransformer to supply reduced voltage when starting the motor. The controller is of the closed circuit type where the motor circuit remains closed during the transition from start to run resulting in minimum line disturbance.The controller monitors, displays and records fire pump system information.The autotransformer has three taps for selection of starting current and torque; 50% tap for 150% current and 25% torque, 65% tap (factory setting) for 250% current and 42% torque and the 80% tap for 384% current and 64% torque.

Submittal Packages
Without Power Transfer Switch
download
With Power Transfer Switch
download
Documents & Drawings
  • Controller Only (PDF File Format)
  • Controller Only (Word File Format)
  • Controller with Power Transfer Switch (PDF File Format)
  • Controller with Power Transfer Switch (Word File Format)
Wiring Schematic - Controller Only
download
Wiring Schematic - Controller With Transfer Switch
download
  • 208V (5-125 HP) | 220-240V (5-125 HP)
  • 208V (150-200 HP) | 220-240V (150-250 HP)
  • 380-400-415V (5-200 HP) | 440-480V (5-250 HP) | 600V (5-350 HP)
  • 380-400-415V (250-450 HP) | 440-480V (300-450 HP) | 600V (400-500 HP)
  • Alarms & Control
  • Line Wire Terminal Capacity
  • Motor Wire Terminal Capacity
  • Transfer Switch Line Wire Terminal Capacity (if required)
  • Transfer Switch Field Connections (if required)
  • 208V (5-30 HP) | 220-240V (5-30 HP) | 380-400-415V (5-60 HP) | 440-480V (5-60 HP) | 600V (5-75 HP)
  • 208V (40-60 HP) | 220-240V (40-75 HP) | 380-400-415V (75-125 HP) | 440-480V (75-150 HP) | 600V (100-200 HP)
  • 208V (75-150 HP) | 220-240V (100-200 HP) | 380-400-415V (150-300 HP) | 440-480V (200-450 HP) | 600V (250-500 HP)
  • 380-400-415V (350 HP)
  • 208V (200 HP) | 220-240V (250 HP) | 380-400-415V (400-450 HP) | 440-480V (500 HP)
  • 208V (5-30 HP) | 220-240V (5-30 HP) | 380-400-415V (5-60 HP) | 440-480V (5-60 HP) | 600V (5-75 HP)
  • 208V (40-60 HP) | 220-240V (40-75 HP) | 380-400-415V (75-125 HP) | 440-480V (75-150 HP) | 600V (100-200 HP)
  • 208V (75-125 HP) | 220-240V (100-125 HP) | 380-400-415V (150-200 HP) | 440-480V (200-250 HP) | 600V (250-350 HP)
  • 208V (150 HP) | 220-240V (150-200 HP) | 380-400-415V (250-300 HP) | 440-480V (300-400 HP) | 600V (400-500 HP)
  • 380-400-415V (350 HP) | 440-480V (450 HP)
  • 208V (200 HP) | 220-240V (250 HP) | 380-400-415V (400-450 HP) | 440-480V (500 HP)
UL Cert. of Compliance
download
Instruction Manuals
Please see the INSTRUCTION MANUALS tab on Main Menu
Go To Tab
Without Power Transfer Switch
With Power Transfer Switch
  • Controller Only (PDF File Format)
  • Controller Only (Word File Format)
  • Controller with Power Transfer Switch (PDF File Format)
  • Controller with Power Transfer Switch (Word File Format)
Wiring Schematic - Controller Only
download
Wiring Schematic - Controller With Transfer Switch
download
  • 208V (5-125 HP) | 220-240V (5-125 HP)
  • 208V (150-200 HP) | 220-240V (150-250 HP)
  • 380-400-415V (5-200 HP) | 440-480V (5-250 HP) | 600V (5-350 HP)
  • 380-400-415V (250-450 HP) | 440-480V (300-450 HP) | 600V (400-500 HP)
  • Alarms & Control
  • Line Wire Terminal Capacity
  • Motor Wire Terminal Capacity
  • Transfer Switch Line Wire Terminal Capacity (if required)
  • Transfer Switch Field Connections (if required)
  • 208V (5-30 HP) | 220-240V (5-30 HP) | 380-400-415V (5-60 HP) | 440-480V (5-60 HP) | 600V (5-75 HP)
  • 208V (40-60 HP) | 220-240V (40-75 HP) | 380-400-415V (75-125 HP) | 440-480V (75-150 HP) | 600V (100-200 HP)
  • 208V (75-150 HP) | 220-240V (100-200 HP) | 380-400-415V (150-300 HP) | 440-480V (200-450 HP) | 600V (250-500 HP)
  • 380-400-415V (350 HP)
  • 208V (200 HP) | 220-240V (250 HP) | 380-400-415V (400-450 HP) | 440-480V (500 HP)
  • 208V (5-30 HP) | 220-240V (5-30 HP) | 380-400-415V (5-60 HP) | 440-480V (5-60 HP) | 600V (5-75 HP)
  • 208V (40-60 HP) | 220-240V (40-75 HP) | 380-400-415V (75-125 HP) | 440-480V (75-150 HP) | 600V (100-200 HP)
  • 208V (75-125 HP) | 220-240V (100-125 HP) | 380-400-415V (150-200 HP) | 440-480V (200-250 HP) | 600V (250-350 HP)
  • 208V (150 HP) | 220-240V (150-200 HP) | 380-400-415V (250-300 HP) | 440-480V (300-400 HP) | 600V (400-500 HP)
  • 380-400-415V (350 HP) | 440-480V (450 HP)
  • 208V (200 HP) | 220-240V (250 HP) | 380-400-415V (400-450 HP) | 440-480V (500 HP)
UL Cert. of Compliance
download
Please see the INSTRUCTION MANUALS tab on Main Menu
Go To Tab

Have a Question? Connect with a Representative.

Firetrol Representatives are factory trained and extremely knowledgeable  about our products.  They provide local support from quotation to installation and beyond.

Contact Us